Air to Air (The specimens remains stationary method)

Classification: Thermal Shock Chamber

The new energy battery test box is mainly used for long-term continuous tests of high temperature, low temperature, damp heat, temperature alternating cycle and other projects of various large batteries.

  • Features
  • Specifications
  • Options
  • > Internal stainless steel,External resistant powder coated
    > 8 inch Lcd touch screen controller
    > Circulation conditioning system
    > The specimens remains stationary
    > Grand viewing window thermally insulated
    > Using damper to achieve conversion between high chamber and low chamber
    > Chamber overtemperature protection
    > Heavy-duty leveling casters 
    > 1 off cable port 2inch dia
    > 2 off shelves, adjustable and removable, support hold over 50lb. 
    > 1 off USB 
    > 1 off RS-485
    > 1 off Ethernet

  • Thermal Shock Chamber (Air to Air type),

    The specimens remains stationary

    Model

    CTS-A

    Internal volumeLitre

    70

    110

    230

    480

    1000

    Temp. range

    Hot chamber: +60℃~+200℃

     

    Cold chamber: -10℃~--70℃

    Temp. pre-heat up time

    Ambient temp. to +200℃within 30min

    Temp. pre-pull down tome

    Ambient temp. to +-70℃within 60min

    Recovery conditions

    Three zone

     

     

    High-Temp. exposure

    +150℃/30min

     

    Ambient-temp. exposure

    Ambient-temp./5min

    Ambient-temp./10min

     

    Low-temp. exposure

    -55℃/30min

     

    Specimens weight(kg)

    (IC)

    2.0

    5

    10

    15

    25

     

    Recovery Time

    Less Than 5min

    Less Than 10min

    Work space

    (mm)

    W

    400

    600

    700

    850

    1200

     

    H

    450

    450

    500

    700

    800

     

    D

    400

    400

    650

    800

    1000

    Operational environment

    Temperature:5℃~35℃;Humidity:≤85%RH;Atmospheric:80~106KPa

    Interior material

    Stainless steel plate

    Exterior material

    Resistant powder coated

    Shelves

    2pcs

    Heater

    Nichrome wire air heater

    Refrigeration system

    Cascade

    cooling

    Water cooled refrigeration

    power

    Three-phase AC 480V±5% 60Hz± 1

    Air source

    Pressure:0.5~.07MPa

  • Work space:Customized
    temperature shock mode:1* 2 Zone
    2*Recovery conditions:High-Temp. exposure: +200℃/30min
                                            Low-temp. exposure: -65℃/30min
    Cooling system:3*Liquid nitrogen cooling system
    Cable port:4* 2inch
                         5* 4inch

Key words:Ventilating aging test chamber environmental test

Leave us a message

%{tishi_zhanwei}%